ZJC-50KV電氣強(qiáng)度測(cè)定儀
一、電氣強(qiáng)度測(cè)定儀概述
采用立式箱體結(jié)構(gòu),極大的節(jié)省試驗(yàn)室內(nèi)占地空間,地腳采用滑輪結(jié)構(gòu),方便移動(dòng)和擺放,避免同類(lèi)廠家生產(chǎn)的臥式設(shè)備,安放時(shí)需要另配安裝臺(tái)的情況,占地空間大,移動(dòng)不方便等缺點(diǎn)。
滿足以下國(guó)標(biāo)
1、GB1408.1-2006《絕緣材料電氣強(qiáng)度試驗(yàn)方法》
2、GB1408.2-2006《絕緣材料電氣強(qiáng)度試驗(yàn)方法
第2部分:對(duì)應(yīng)用直流電壓試驗(yàn)的附加要求》
3、GB/T1695-2005《硫化橡膠工頻擊穿電壓強(qiáng)度和耐電壓的測(cè)定方法》
4、GB/T3333 電纜紙工頻電壓擊穿試驗(yàn)方法
5、HG/T 3330絕緣漆漆膜擊穿強(qiáng)度測(cè)定法
6、GB12656 電容器紙工頻電壓擊穿試驗(yàn)方法
7、ASTM D149《固體電絕緣材料工業(yè)電源頻率下的介電擊穿電壓和介電強(qiáng)度的試驗(yàn)方法》
主要適用于固體絕緣材料如:塑料薄膜、樹(shù)脂、云母、陶瓷、玻璃、絕緣油、絕緣漆、紙板等介質(zhì)在工頻電壓或直流電壓下?lián)舸?qiáng)度和耐電壓時(shí)間的測(cè)試;介電強(qiáng)度測(cè)試儀采用計(jì)算機(jī)控制,試驗(yàn)過(guò)程中可在線觀察試驗(yàn)曲線;自動(dòng)存儲(chǔ)試驗(yàn)條件及試驗(yàn)結(jié)果等數(shù)據(jù),并可存取、顯示、打印。
二、主要技術(shù)要求:
序號(hào) | 項(xiàng)目 | 參數(shù) |
1 | 設(shè)備輸入電壓 | 交流 50KV |
2 | 試驗(yàn)電壓方式 | 交流 0--50 KV ;直流 0--20 KV |
3 | 電器容量 | 10KVA |
4 | 試驗(yàn)方法 | 0-50KV全量程可調(diào) |
5 | 擊穿及耐壓試驗(yàn)升壓速率 | 0.1 KV/S-3.0 KV/S可調(diào) |
6 | 試驗(yàn)方式 | 直流試驗(yàn) 交流試驗(yàn) |
7 | 漏電電流選擇 | 1—100 mA |
8 | 電壓測(cè)量誤差 | ≤ 1.5% |
9 | 試驗(yàn)電壓連續(xù)可調(diào) | 0-100 KV |
10 | 耐壓時(shí)間設(shè)定 | 0-6小時(shí) |
11 | 九級(jí)安全防護(hù)措施 | (1) 超壓保護(hù) |
12 |
| (2)試驗(yàn)過(guò)流保護(hù) |
13 |
| (3)試驗(yàn)短路保護(hù) |
14 |
| (4)安全門(mén)開(kāi)啟保護(hù) |
15 |
| (5)軟件誤操作保護(hù) |
16 |
| (6)零電壓復(fù)位保護(hù) |
17 |
| (7)試驗(yàn)結(jié)束放電保護(hù) |
18 | (9)試驗(yàn)完成后電磁放電 | (8)獨(dú)立保護(hù)接地 |
三、試驗(yàn)方式
1、絕緣試樣空氣中擊穿或耐壓試驗(yàn)
2、絕緣試樣浸油中擊穿或耐壓試驗(yàn)
3、絕緣試樣空氣中階梯擊穿或耐壓試驗(yàn)
4、絕緣試樣浸油中階梯擊穿或耐壓試驗(yàn)
注:根據(jù)用戶(hù)要求,可定制其他試驗(yàn)方式
四、試驗(yàn)軟件:
1、本儀器在試驗(yàn)過(guò)程中可對(duì)升壓擊穿過(guò)程繪制實(shí)時(shí)曲線,每次試驗(yàn)的升壓曲線都由不同顏色構(gòu)成,試驗(yàn)結(jié)束后可疊加對(duì)比材料的試驗(yàn)數(shù)據(jù)重復(fù)性。
2、可以隨時(shí)調(diào)取當(dāng)前及歷史試驗(yàn)數(shù)據(jù)進(jìn)行查看,編輯及修改參數(shù)。
3、試驗(yàn)過(guò)程中可以隨時(shí)修改試驗(yàn)條件及存儲(chǔ)路徑及自動(dòng)存儲(chǔ)試驗(yàn)結(jié)果。
4、試驗(yàn)過(guò)程中,可隨時(shí)通過(guò)軟件決定本次試驗(yàn)是否有效,方便篩選試驗(yàn)結(jié)果。
5、可設(shè)置操作口令,做到專(zhuān)機(jī)專(zhuān)人操作,避免無(wú)關(guān)人員誤操作。
五、常規(guī)型號(hào):
ZJC-10KV
ZJC-20KV
ZJC-50KV
ZJC-100KV
ZJC-150KV
六、主要配置:
序號(hào) | 配置 | 數(shù)量 | 單位 |
1 | 試驗(yàn)主機(jī) | 1 | 臺(tái) |
2 | 5萬(wàn)伏高壓發(fā)生器 | 1 | 臺(tái) |
3 | 全自動(dòng)微電腦電壓調(diào)壓裝置 | 1 | 套 |
4 | 試驗(yàn)電極 | 2 | 套 |
5 | 試驗(yàn)用油盒 | 1 | 只 |
6 | 電磁自動(dòng)放電裝置 | 1 | 套 |
7 | 電壓擊穿計(jì)算機(jī)測(cè)控軟件 | 1 | 套 |
8 | 計(jì)算機(jī) | 1 | 套 |
9 | 彩色噴墨打印機(jī) | 1 | 臺(tái) |
10 | *計(jì)量鑒定質(zhì)檢證書(shū) | 1 | 份 |
11 | 產(chǎn)品使用說(shuō)明書(shū) | 1 | 份 |
12 | 合格證 | 1 | 份 |
七、注意事項(xiàng):
1、儀器安裝時(shí)應(yīng)具有獨(dú)立的接地線。
2、在開(kāi)機(jī)前,操作者要首先熟悉操作方法。
3、儀器不能在有強(qiáng)烈腐蝕性氣體及有顆粒雜質(zhì)的氣體環(huán)境中使用。
4、試驗(yàn)環(huán)境溫度15度到25度之間,相對(duì)濕度60%到70%之間
5、試樣擊穿瞬間有火花產(chǎn)生并伴有聲響,屬正?,F(xiàn)象。
6、每次更換試樣或接觸高壓電極時(shí)必須用高壓放電棒對(duì)高壓電極進(jìn)行放電,放電時(shí)間5秒以上。
7、每次進(jìn)行試驗(yàn)前,必須檢查儀器接地。
One, the main applicable scope and function
Meet the GB/T1695-2005 vulcanized rubber power frequency voltage breakdown strength andvoltage resistance test GB/T intensity of 1408-2006 testing methods for insulating material strength GB/T3333 cable paper industrial frequency voltage breakdown test method HG/T 3330 insulation paint film breakdown strength determination method of GB12656 capacitor paperelectric pressure test method for breakdown and ASTM D149 standard requirements. Mainly applicable to solid insulating materials such as: resin and rubber, impregnated fiber product,plastic composite products, film, resin, mica, ceramic, glass, insulating paint and other media in the frequency of the voltage or DC voltage breakdown strength and voltage resistance test of time.
Two, the software of the control function:
1 the equipment during the test can be dynamically draw the test curve, the curve can be a variety of color overlay test comparison.
2 can be edited on the test data, flexible application;
3 the test conditions and test results data can be stored automatically;
The 4 test report format is flexible, suitable for different requirements of different users.
5 a group of curves of test data is effective or not artificially selected.
6 test results data can be imported into EXECL.
Three, equipment safety protection function:
1, equipment to install a separate protective ground, mainly is the strong electromagnetic interference to reduce the sample breakdown when the surrounding the. Also avoid control computer control.
In 2, DC discharge alarm function: in the equipment finished the DC test, when opening the doorwhen the test equipment will automatically alarm, discharge device discharge until useequipment after the alarm will be cancelled automatically. (Note: because the DC test and not put electricity danger to personal safety, can not directly get electrode, a reminder to use staff in order to avoid personal injury) Adult discharge.
3, with the test manual discharging device, with the host for the integration, when a sudden blackout DC test process, can adopt manual discharging rod discharge test, ensure the personal safety.
Circuit 4, the test equipment is provided with a number of protective measures are: over-current protection, under voltage protection, leakage protection, short-circuit protection, DC dischargeprotection etc..
Four, the main technical requirements:
01, the input voltage: 220V
02, the output voltage: AC 0--50 KV;
03, electrical capacity: 5KVA
04, high grade: 0--5KV; 0-10KV; 0--20KV; 0--50KV;
05, the rate of pressure rise: 10-5000 V/S (you can set different step-up rate according to user needs)
06, test mode: DC test: 1, 2, 3 speed boost pressure gradient, pressure test
AC test: 1, 2, 3 speed boost pressure gradient, pressure test
Over current protection device 07, the installation of high sensitivity to ensure the power supply is cut off in the 0.1S sample breakdown
08, the use of advanced contactless original uniform pressure.
09, support for a short time short-circuit test requirements.
10, the electrode specifications: Phi 25mm two sheet electrodes of 75mm a (can be produced according to customer requirements)
11, host size: 900*800*1500mm long width height
12, the operating table size: 900*700*1500mm long width height
13, the protective cover material: white transparent organic glass
14, the oil groove size: length width height 100*80*80
15, weight: about 100KG
產(chǎn)品咨詢(xún)
歡迎您關(guān)注我們的微信公眾號(hào)了解更多信息
電話
微信掃一掃